The sound reinforcement characteristic index of the hall shall be carried out in accordance with the requirements of the national first-level characteristic index. details as follows:

Technical index

The sound reinforcement characteristic index of the hall shall be carried out in accordance with the requirements of the national first-level characteristic index. details as follows:

Level 1 characteristic index requirements:

Maximum sound pressure level: greater than or equal to 110dB;

Transmission frequency characteristics: the average sound pressure level of 100~6300Hz is 0dB, within this range +/- 4dB is allowed, and 50Hz-10000Hz is allowed +4~-8dB;

Sound transmission gain: -8dB, 125Hz~4000Hz;

Sound field unevenness: less than or equal to 8dB, 1000~4000Hz;

Total noise level: less than or equal to 30dB (A).